Silent Knight 5700 IntelliKnight RB (w/ Silent Knight and Hochiki Programming)
$2,000.00
The Silent Knight 5700 IntelliKnight RB is the main replacement board for 5700 single-loop addressable fire alarm control panels that support both Silent Knight "SK" and Hochiki "SD" device programming. This version is intended for systems using either SK-series or SD-series addressable detectors and modules, with a built-in dual-line communicator, onboard LCD interface, and integrated notification power.
Key Specifications:
Type: Intelligent addressable FACP replacement board with built-in DACT
Device Capacity (SK protocol): Up to 50 SK detectors + 50 SK modules
Device Capacity (SD protocol): Up to 50 SD addressable devices
Loop/Protocol: Single SLC; supports Silent Knight SK protocol or Hochiki SD protocol programming
NAC Circuits: Two Class B Style Y circuits or one Class A Style Z circuit; configurable for notification or auxiliary power
I/O & Synchronization: Built-in synchronization for AMSECO, Gentex, Faraday, System Sensor, and Wheelock appliances
Power: 120 VAC, 60 Hz, 1.5 A primary input; 2.5 A at 27.4 VDC notification power
System Output: 2.5 A total accessory load at 27.4 VDC
Battery Support: 7 to 35 Ah charging capacity; 7 Ah max in main cabinet, larger batteries require RBB
Indicators/UI: Built-in 80-character LCD annunciator and keypad
Ports: RS-232 for PC programming; RS-485 for system accessories
Relays: One Form-C trouble relay and two Form-C programmable relays, rated 2.5 A at 27.4 VDC
Dialer/Communicator: Built-in dual-line digital communicator
Compatible Modules & Accessories:
5860 - LCD remote annunciator, gray
5860R - LCD remote annunciator, red
5496 - 6 A intelligent notification power module
5880 - LED I/O module
5883 - 10-relay interface board
5895XL - Intelligent power module
Compatible Detectors & Devices:
SK-PHOTO-W - Photoelectric smoke detector
SK-PHOTO-T-W - Photoelectric smoke + heat detector
SK-HEAT-W - Fixed-temperature heat detector
SK-HEAT-ROR-W - Rate-of-rise heat detector
Also compatible with SD-series (Hochiki protocol) detectors and modules when the panel is programmed for SD devices. SK and SD devices cannot be mixed on the same FACP.
Compatible for use with:
-
Silent Knight 5496 Intelligent Power Module w/ Cabinet (6 Dip Switch)$600.00Condition: RefurbishedOut of stock -
Silent Knight 5496 Intelligent Power Module (5 Dip Switch)$500.00Condition: RefurbishedOut of stock -
Silent Knight 5880 IntelliKnight LED Input/Output Module$400.00Condition: RefurbishedOut of stock -
Silent Knight 5496 Intelligent Power Module (6 Dip Switch)$500.00Condition: RefurbishedOut of stock
![Silent Knight 5883 Relay Interface Board [NEW]](https://www.buyfirealarmparts.com/shop/pub/media/catalog/product/cache/b7d609d7df38a098e26ffd0519e3edb1/1/_/1_2.png)