Kidde FX-64-RE (Intelligent FACP) Replacement Electronics

$950.00

Availability

2 In Stock

Condition

New

Warranty

90 Days
The Kidde FX-64-RE is replacement electronics for Kidde FX-64 series intelligent addressable fire alarm control panels. It comes with one 64-point loop and supports one Class A or Class B SLC loop for up to 64 addressable devices in any combination of detectors and modules. When installed in a compatible FX-64 cabinet, the electronics support two onboard NACs with 3.75 A total notification power, two 27.4 V DC auxiliary outputs, optional SA-DACT dialer, and optional SA-CLA Class A NAC conversion. Replacement electronics only; cabinet, door, batteries, transformer, and optional cards are not included. Model Variants: FX-64R = Complete 64-point panel, no dialer FX-64RD = Complete 64-point panel with dual-line dialer included FX-64-RE = Replacement electronics with one 64-point loop Key Specifications: Type: Intelligent addressable FACP replacement electronics Included Hardware: Replacement electronics with one 64-point loop Point Capacity: 64 addressable devices SLC Loops: 1 Class A/B loop, not expandable NAC Circuits: 2 Class B or Class A with SA-CLA, 2.5 A per circuit, 3.75 A total Primary Power: Uses existing FX-64 cabinet power connection; FX-64 system rating is 120 VAC 60 Hz, 1.3 A max Accessory Power: Two 27.4 V DC auxiliary outputs, 500 mA each Battery Support: FX-64 system supports two 10 Ah internal batteries, 26 Ah charging capacity Communicator: Optional SA-DACT dual-line dialer/modem (Contact ID) Compatible Modules & Accessories: SA-DACT - Dual-line dialer/modem option card SA-ETH - Ethernet interface SA-232 - RS-232 printer/computer interface SA-CLA - Class A NAC adapter CTM - City-tie module BC-1R - 24 Ah battery cabinet MFC-A - Multifunction auxiliary cabinet Compatible Detectors & Devices: KI-OSD - Optical smoke detector KI-OSHD - Optical smoke / fixed-temperature heat detector KI-OSCD - Optical smoke + CO detector KI-HRD - Rate-of-rise heat detector KI-HFD - Fixed-temperature heat detector KI-HCD - Heat + CO detector KIR-OSD - Optical smoke detector with rotary addressing KIR-HD - Fixed-temperature / rate-of-rise heat detector with rotary addressing KIR-HCD - Heat + CO detector with rotary addressing KI-SB - Standard base KI-IB - Isolator base KI-RB - Relay base KI-ABST - Sounder base FX-270 - Single-action addressable pull station FX-278 - Dual-action addressable pull station
Kidde FX-64-RE (Intelligent FACP) Replacement Electronics

More Views